Raritan PCS12 User's Guide Page 67

  • Download
  • Add to my manuals
  • Print
  • Page
    / 70
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 66
Appendix C: CC-SG and Network Configuration
67
Communication Direction Port Number Protocol Configurable? Details
CC-SG to DRAC 80 or 443 TCP no Vendor standard
CC-SG to RSA 80 or 443 TCP no Vendor standard
CC-SG and SNMP
Simple Network Management Protocol (SNMP) allows CC-SG to push
SNMP traps (event notifications) to an existing SNMP manager on the
network. CC-SG also supports SNMP GET/SET operations with
third-party Enterprise Management Solutions such as HP OpenView.
Communication
Direction
Port Number Protocol Configurable? Details
SNMP Manager to
CC-SG
161 UDP yes SNMP standard
CC-SG to SNMP
Manager
162 UDP yes SNMP standard
CC-SG and CC-NOC
CC-NOC is an optional appliance that can be deployed in conjunction
with CC-SG. CC-NOC is a Raritan network-monitoring appliance that
audits and monitors the status of servers, equipment, and Raritan
devices that CC-SG manages.
Communication
Direction
Port Number Protocol Configurable? Details
CC-SG to CC-NOC 9443 TCP no NOC web services.
SSL/AES128
encrypted.
Page view 66
1 2 ... 62 63 64 65 66 67 68 69 70