Raritan PCS12 User's Guide Page 64

  • Download
  • Add to my manuals
  • Print
  • Page
    / 70
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 63
Appendix C: CC-SG and Network Configuration
64
Communication Direction Port Number Protocol Configurable? Details
CC-SG to Raritan Device 5000 TCP yes RDM protocol
RC4/AES128
encrypted
Raritan Device to CC-SG 5001 UDP no heartbeat
CC-SG to Dominion PX 623 UDP no
CC-SG Clustering
When the optional CC-SG clustering feature is used, the following ports
must be available for the inter-connecting sub-networks. If the optional
clustering feature is not used, none of these ports has to be open.
Each CC-SG in the cluster may be on a separate LAN. However, the
inter-connection between the units should be very reliable and not prone
to periods of congestion.
Communication Direction Port
Number
Protocol Configurable? Details
CC-SG to Local Broadcast 10000 UDP no heartbeat
CC-SG to Remote LAN IP 10000 UDP no heartbeat
CC-SG to CC-SG 5432 TCP no From HA-JDBC on
Primary to Backup
PostgreSQL DB
server.
Not encrypted.
CC-SG to CC-SG 8732 TCP no Primary-Backup
server synch
clustering control
data exchange.
MD5 encrypted.
CC-SG to CC-SG 3232 TCP no Primary-Backup
SNMP synch
configuration
changes forwarding.
Not encrypted.
Page view 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 70