Chapter 6. Menu Options
The following events are reported by the ASMI module via SNMP:
Login attempt to the ASMI module failed.
Login attempt to the ASMI module succeeded.
Denying access to a particular action.
Server was reset.
Server was powered on/off.
The SNMP settings panel as shown in
Figure 6-35 is described below. It allows you to change SNMP
related parameters.
Enable SNMP Agent
If this option is checked the ASMI module will reply to SNMP requests.
Tip: If a community is left blank, you cannot perform the according request. E.g. if you want to
disable the possibility to reset the ASMI module via SNMP then do not set a write community.
Read Community
This is the SNMP community which allows you to retrieve information via SNMP.
Write Community
This community allows you to set options and to reset the ASMI module or the host via SNMP, i.e.
everything that affects the remote host or the ASMI module.
System Location
Enter a description of the physical location of the host. The description will be used in the reply to
an SNMP request "sysLocation.0".
System Contact
Enter a contact person for the host. The value will be used in reply to the SNMP request
"sysContact.0".
The ASMI module SNMP MIB
This link allows you to download the ASMI module’s SNMP MIB file. This file may be necessary
for an SNMP client to communicate with the ASMI module.