Raritan DOMINION SX - Specifications Page 47

  • Download
  • Add to my manuals
  • Print
  • Page
    / 178
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 46
CHAPTER 4: CONSOLE FEATURES 37
TCP/IP network may be set to listen to broadcasts on this address; if this is the case, it can be
configured to use another port address. However, this port address MUST match the port address
specified by the CC administrator; otherwise the Dominion SX unit will not be discovered by CC. This
port address is relevant only for CC releases 2.3 or higher.
Click on the [Update] button to load all the changes.
Click on the [Save] button to make the changes permanent.
Important! Remember that saving changes to Network Configuration settings will cause the unit
to reboot.
The parameters for configuring modem access include:
PARAMETER DESCRIPTION
Enable Modem Configures the modem to answer calls
PPP Server IP IP address of the PPP server (Dominion SX unit)
PPP Client IP IP address of the PPP client (remote computer)
Enable modem Dial Back Enables Modem dial back (phone number for
modem dial back is specified in the CLI using
SSH [or telnet, if enabled]).
Configure Modem Parameters
1. Check the Enable Modem box.
Note: Click on the checkbox before Enable Modem Dial Back and type the phone number for dial back
using the command line interface (SSH/telnet). Enabling Modem Dial Back potentially enhances security,
and is recommended for most applications.
2. Type the PPP Server IP address used by the client to access Dominion SX once the modem
connection is established.
3. Type the PPP Client IP address assigned by Dominion SX to the client in order for the connection to
be established.
4. Click Update.
5. Click Save.
6. Optionally, enable modem dial back and type the phone number for dial back using the CLI
(SSH/telnet). Using modem dial back can potentially enhance security, and is recommended for most
applications.
The Modem Status field indicates one of two states:
Running: The modem is configured and is operational.
Stopped: The modem is not operational.
The [Initialize Modem] button can be used to reset the modem if it is running but not operating properly.
Note: Be sure to verify the above information with your Network Administrator prior to configuring the
unit.
When using Microsoft Windows, once Microsoft dial-up networking has established a connection, a
network is constructed with the parameters specified in the Modem Settings area of the Network
configuration window. The client computer now can be connected to two separate networks. These
networks must have distinct IP addresses if modem access is to function properly. The second network
established by the PPP connection has only two devices, the Dominion SX unit with IP address PPP Server
IP and the client computer with IP address PPP Client IP.
Please see Appendix G: Modem Configuration for additional information on configuring Microsoft dial-
up networking on Windows 2000, Windows 98, and Windows NT.
Page view 46